Email ion
Skype ion
Call ion: +1.631.630.0600

LinkedIN Twitter Google+

SR-71mach6 SpeedServer™ ion's all-SSD Server

ion's SR-71mach6 SpeedServer™ is an all SSD server optimized to deliver over 2 million IOPS performing 8kB random reads. ion's SpeedServer is built on the latest Intel® Xeon® Scalable processors with up to 1.5TB of the fastest memory along with 10Gb, 25Gb and 40Gb server NICs in a compact, cost-effective, and low-power system.

ion SR-71mach6 SpeedServer(TM) image
  • Design your ultimate servers based on SSD RAID in the SR-71mach6 Configurator.
  • Need more modest capacity, lower cost or smaller size? SR-70mach6 SpeedServer.
  • No fabric can deliver latency as low as NVMe direct-attached storage (DAS).
  • ion SR-71mach6 SpeedServer is based on Intel® Data Center SSDs with an Uncorrectable Bit Error Rate (UBER/NRE) of 1 sector per 1017 bits read.

"All-Flash Array, or AFA"? All SSD, yes, but ion's SR-71mach6 SpeedServer™ can be designed with Intel® DC Flash SSDs and/or Intel® Optane SSDs based on 3D XPoint technology for even higher performance than Flash. ion's SR-71mach6 SpeedServer is a server, not just an array or storage subsystem. Software like Open-E JovianDSS or Microsoft® Windows® Storage Spaces Direct (S2D) can present the server as a storage resource; VMware® vSAN can provision the SR-71mach6 SpeedServer as hyper-converged infrastructure (HCI). Or, for a speedy virtual machine host, Microsoft® Windows® Hyper-V® or Linux® deliver very flexible platforms.

What would an All-SSD server do for the performance of your database? An All-SSD File Server? Or, an All-SSD Open-E JovianDSS storage server? Considering other products? ion's SR-71mach6 SpeedServer™ is a server running the operating system of your choice with no secret sauce.

Sure, you can still deploy servers with spinning rust. But why? Pretend for a moment that the performance of an all-SSD server - very high IOPS, very low latency and amazing bandwidth - is of no value to your organization. What is the value of the higher reliability of SSDs? What tolerance does your organization have for downtime? For slow RAID rebuilds? SR-71mach6 SpeedServer is built entirely with SSD, using RAID, to produce a storage server of very high reliability. SpeedServer? StorageServer? SR-71mach6 is a server, SSD-optimized for the highest performance possible.

Contact ion to take the SR-71mach6 SpeedServer for a testdrive!

ION SR-71mach6 SpeedServer is built exclusively with Intel SSDs.
ION SR-71mach6 SpeedServer starts with an Intel ServerBoard.
In 1998, ION became the first company in the world to qualify as an Intel Authorized Solution Provider, the program now known as Intel Technology Provider, Platinum Member.

CRN Test Center
"2015 Products
of the Year"

SR-71mach6
Product Brief

ion Server Blog

 

  1. mach6 Windows IOmeter
  2. mach6 Linux fio
  3. mach4 iSCSI Target
  4. mach3 FC Target
  5. Benchmarks
Certified by Open-E, 2014-June-23
ION SR-71mach4 SpeedServer as iSCSI Target with Open-E DSS V7, RAID 5 Summary
4 Server Initiators
(2) 10GbE iSCSI MPIO connections each
24 x 200GiB RAID5 Targets
6 Tgts per Initiators, 2 Workers per target
IOPS MBps Latency, ms
64kB Random Write,Q=8 22,862 1,429 16.8
64kB Random Read,Q=8 123,264 7,704 3.11
32kB Random Read,Q=8 235,176 7,349 1.63
16kB Random Read,Q=8 321,134 5,018 1.19
8kB Random Read,Q=8 348,960 2,726 1.10
4kB Random Read,Q=8 340,369 1,330 1.13
8kB OLTP,Q=8 194,503 1,520 1.97
64kB OLTP, Q=8 46,327 2,895 8.29
Web Server, Q=8 301,727 4,615 1.27
IOmeter report June 2014
4 Server Initiators
(2) 10GbE iSCSI MPIO connections each
24 x 200GiB RAID5 Targets
6 Tgts per Initiator, 1 Worker per target
IOPS MBps Latency, ms
1MB Seq. Write,Q=8 2,185 2,185 88
256kB Seq. Write,Q=16 14,215 3,554 27
64kB Seq. Write,Q=16 13,713 857 28
1MB Seq. Read,Q=2 6,212 6,212 7.7
256kB Seq. Read,Q=8 26,160 6,540 7.34
64kB Seq. Read,Q=32 125,907 7,869 6.1
IOmeter report June 2014
4 Server Initiators
(2) 10GbE iSCSI MPIO connections each
32 x 200GiB RAID5 Targets
8 Tgts per Initiator, 2 Workers per Target
IOPS MBps Latency, ms
64kB Random Write,Q=8 21,236 1,327 24.1
64kB Random Read,Q=8 127,967 7,998 4.00
32kB Random Read,Q=8 245,193 7,662 2.09
16kB Random Read,Q=8 353,921 5,530 1.45
8kB Random Read,Q=8 376,637 2,942 1.36
4kB Random Read,Q=8 374,171 1,462 1.37
8kB OLTP,Q=8 189,939 1,484 2.69
64kB OLTP, Q=8 42,124 2,633 12.2
Web Server, Q=8 332,799 5,089 1.54
IOmeter report June 2014
4 Server Initiators
(2) 10GbE iSCSI MPIO connections each
32 x 200GiB RAID5 Targets
8 Tgts per Initiator, 2 Workers per Target
IOPS MBps Latency, ms
64kB Random Write,Q=1 13,819 863 4.6
64kB Random Read,Q=1 62,123 3,883 1.03
32kB Random Read,Q=1 90,481 2,828 0.71
16kB Random Read,Q=1 121,662 1,901 0.52
8kB Random Read,Q=1 151,760 1,186 0.42
4kB Random Read,Q=1 141,924 554 0.45
8kB OLTP,Q=1 88,064 688 0.73
64kB OLTP, Q=1 26,858 1,679 2.38
Web Server, Q=1 123,193 51,884 0.52