Email ion
Skype ion
Call ion: +1.631.630.0600
LinkedIN Twitter Google+

ion SR-71mach5 SpeedServer™
All-SSD RAID Server

SR-71mach5 SpeedServer(TM) ion's SR-71mach5 SpeedServer™ is an all-SSD RAID server optimized to deliver more than 1 Million random read IOPS based on fast processors, memory, and network components in a compact, cost-effective, and low-power system. If latency matters to your application, you should consider running that application ON the SR-71mach5 SpeedServer directly or deploying SR-71mach5 file servers. DAS or NAS or SAN?

 

Your challenge: Build the fastest server possible?

SR-71mach5 SpeedServer More Cores? RAM? NVMe? SSDs? NICs?
  • 24 Intel® Xeon® V4 cores
  • 128GB DDR4 RAM
  • 28TB SSD RAID Storage
  • >1M random IOPS
  • (4) 10Gb Ethernet ports
  • 16-44 Intel® Xeon® V4 cores
  • Up to 1536GB DDR4 RAM
  • Up to 165TB with SSD RAID shelves
  • Up to (8) U.2 NVMe SSDs
  • Up to (14) 10Gb Ethernet ports

The SR-71mach5 SpeedServer makes disk-impossible performance affordable for your data center through the optimized use of SSD RAID and standard high-volume server building blocks from Intel. Yes, this webserver and blog.ioncomputer.com are both VMs on an SR-71 SpeedServer.

ION's SR-71mach5 SpeedServer is built exclusively with Intel SSDs.
ION's SR-71mach5 SpeedServer starts with an Intel ServerBoard.
In 1998, ION became the first company in the world to qualify as an Intel Authorized Solution Provider, the program now known as Intel Technology Provide, Platinum Member.

The SR-71mach5 SpeedServer as a Windows® Server 2012 R2 file server delivers 197,000 IOPS to (5) IOmeter clients performing an 8kB random read/write (IOMeter OLTP) benchmark, with just 1.2 ms average latency.


Design your ultimate server with our SR-71mach5 Configurator.

For a powerful but less expensive 1U all-SSD RAID server, look at the SR-70mach5 SpeedServer.

Hard to believe this performance? Especially at that price? Take the SR-71mach5 SpeedServer for a testdrive!

CRN Test Center
"2015 Products
of the Year"

SR-71mach5
Product Brief

Learn more at
ion Server Blog

 

  1. mach5 RAID 5 IOmeter
  2. mach4 RAID 10 IOmeter
  3. mach5 SQLIO
  4. mach5 RAID 5 Linux
  5. mach5 RAID 5 Windows Server
  6. mach4 iSCSI Target
  7. mach3 FC Target
  8. Benchmarks
SR-71mach5 SpeedServer running CentOS Linux® 7.1
SR-71mach5 with (3) RAID 5 Volumes with (5) 1.75TB partitions each, XFS
fio 2.0.10
Block
Size
 
Test
 Num
Jobs
 # I/Os
Queued
 
IOPS
 
MBps
Latency (μsec)
8kB Random Write 1 1 45248 352 329
64kB Random Write 1 1 23038 1439 647
8kB Random Read/Write (67%/33%) 2 2 104713 816 1074
64kB Random Read/Write (67%/33%) 2 2 39651 2475 2339
1MB Sequential Write 1 2 5335 5335 5627
1MB Sequential Read 1 4 10851 10851 5526
256kB Sequential Write 1 2 33062 8264 904
256kB Sequential Read 1 4 35237 8808 1700
256kB Sequential Read 1 14 43297 10823 4848
64kB Sequential Write 1 4 118831 7425 503
64kB Sequential Read 1 4 92764 5796 645
64kB Sequential Read 1 16 154264 9640 1554
64kB Random Read 1 8 128025 8000 935
64kB Random Read 4 4 153082 9566 1566
32kB Random Read 2 8 286734 8959 835
32kB Random Read 4 8 309483 9670 1549
16kB Random Read 2 8 448881 7013 533
8kB Random Read 4 2 455924 3560 261
8kB Random Read 4 4 474122 3703 504
4kB Random Read 2 4 474274 1851 251
4kB Random Read 4 6 487307 1902 737
SR-71mach5 Linux fio result details, December 2015
SR-71mach5 SpeedServer running CentOS Linux® 6.7
SR-71mach5 with (3) RAID 5 Volumes with (5) 1.75TB partitions each, XFS
fio 2.0.10
Block
Size
 
Test
 Num
Jobs
 # I/Os
Queued
 
IOPS
 
MBps
Latency (μsec)
1MB Sequential Write 1 2 6,777 6,777 4,436
1MB Sequential Read 1 4 10,852 10,852 5,527
256kB Sequential Write 1 2 33,182 8,294 902
256kB Sequential Read 1 10 42,675 10,668 3,513
64kB Sequential Write 1 6 122,069 7628 735
64kB Sequential Read 1 16 154,330 9,644 1,553
8kB Random Write 1 2 47,825 373 625
64kB Random Write 1 2 21,566 1,346 1,390
64kB Random Read 2 10 156,995 9,812 1,909
32kB Random Read 4 6 305,826 9,556 1,175
16kB Random Read 2 14 463,977 7,249 903
8kB Random Read 3 6 287,162 2,242 948
4kB Random Read 3 8 322,970 1,260 1,118
8kB Random Read/Write (67%/33%) 4 2 112,630 877 2,076
64kB Random Read/Write (67%/33%) 1 8 44,919 2,805 4,142
SR-71mach5 Linux fio result details, November 2015
SR-71mach4 SpeedServer running CentOS Linux® 7.0
SR-71mach4 with (3) RAID 5 Volumes with (4) 1TB partitions each, XFS
fio 2.0.10
 
IOPS
 
MBps
Latency,
(ms)
 
256kB Sequential Write,Q=12 25,582 6,395 5.63
256kB Sequential Read,Q=10 40,800 10,200 2.94
 64kB OLTP(67%R/33%W),Q=8 28,370 1,773 5.12
 64kB Random Read,Q=12 150,749 9,421 1.91
  8kB OLTP(67%R/33%W),Q=6 169,948 1,327 0.70
  8kB Random Read,Q=4 551,190 4,306 0.35
SR-71mach4 Linux fio result details, December 2014
 
SR-71mach4 SpeedServer running CentOS Linux® 6.4
SR-71mach4 with 3 RAID 5 Volumes, 2 NFS4 Shares on each & (6) 10GbE NICs;
3 clients, each with (2) 10GbE NICs.
3 x 4000GB SSD RAID 5, 2 NFS4 shares each
fio 2.0.10
 
IOPS
 
MBps
Latency,
(ms)
   64kB OLTP(R/W),Q=4 3,558 222 24.54
 64kB Random Read,Q=4 81,673 5,104 0.88
 8kB Random Read,Q=12 220,863 1,725 0.65
SR-71mach4 Linux NFS4 fio results, December 2013

ION Home Page